High-Accuracy Augmented Reality Guidance for Intracranial Drain Placement Using a Standalone Head-Worn Navigation System: First-in-Human Results
 
High-Accuracy Augmented Reality Guidance for Intracranial Drain Placement Using a Standalone Head-Worn Navigation System: First-in-Human Results 
 
Frederick Van Gestel, Frederick Van Gestel, Taylor Frantz, Taylor Frantz, Félix Buyck, Félix Buyck, Anthony G Gallagher, Anthony G Gallagher, Wietse Geens, Wietse Geens, Quentin Neuville, Quentin Neuville, Michael Bruneau, Michael Bruneau, Bart Jansen, Bart Jansen, Thierry Scheerlinck, Thierry Scheerlinck, Jef Vandemeulebroucke, Jef Vandemeulebroucke, Johnny Duerinck, Johnny Duerinck
 
Abstract 

BACKGROUND AND OBJECTIVES: External ventricular drain (EVD) placement is often performed freehand, a technique subpar to accurate yet impractical image-guided methods, yielding optimal placement in only 70\%. The aim of this study was to address shortcomings in EVD placement and image guidance technologies by implementing high-accuracy augmented reality (AR) guidance.METHODS: We conducted a prospective clinical pilot study to assess feasibility, safety, and clinical performance of EVD placement using a standalone AR headset equipped with high-accuracy inside-out infrared tracking and software addressing EVD placement. Placement quality was reported using a newly defined extended modified Kakarla scale, and dichotomized into clinically relevant outcome parameters. Results were compared with a nonconcurrent freehand control group using one-sided Fisher exact tests.RESULTS: Eleven AR-guided EVD placements were performed, achieving functional placement in all cases on the first attempt, vs 7 (64\%) in the control group (P = .045); successful placement in 9 (82\%) vs 5 (45\%); optimal in 8 (73\%) vs 3 (27\%) (P = .043); suboptimal in 2 (18\%) vs 5 (45\%); and failed in 0 vs 1 (9\%). No AR-guided placements required revision, whereas the freehand group had a 36\% reintervention rate (P = .045). Procedure-related complications occurred in 2 AR-guided cases (18\%), vs 5 (45\%) freehand (all post-reintervention).CONCLUSION: This study presents the first clinical use case of EVD placement using high-accuracy AR guidance contained in a standalone head-worn navigation system. Safe and reliable outcomes using a validated pipeline were demonstrated, eliminating stick-and-poke attempts and resulting in improved quality, increased single attempt success rates, and reduced revision and complication rates. Based on these results, a multicenter randomized controlled trial will be initiated.