Application of desktop micro-CT imaging as gold standard in caries diagnosis
 
Application of desktop micro-CT imaging as gold standard in caries diagnosis ■
 
Peter Bottenberg, Peter Bottenberg, Peter Bottenberg, Lucia Henin, Lucia Henin, Lucia Henin, Cristina Boca, Cristina Boca, Cristina Boca, Andrei Postnov, Andrei Postnov, Andrei Postnov, Adam Wasek, Adam Wasek, Adam Wasek, Nora De Clerck, Nora De Clerck, Nora De Clerck, Bart Truyen, Bart Truyen, Bart Truyen
 
Abstract ■

Objectives: Conventionally, 'gold standards' used in the evaluation of different caries diagnosis techniques are based on histological sectioning. Such a procedure, however, requires cumbersome sample preparation, and induces tissue loss and irreversible sample destruction. Micro Computed Tomograhy (micro-CT) allows nondestructive imaging of the internal tooth structure, with information being visualized either as discrete sections or as 3D volume renderings.Methods: Micro-CT images were compared to clinical and histological evaluations of 16 extracted teeth, encompassing different pathologies. Clinical evaluation was performed by a panel of three dentists and three graduate students on models containing 3 teeth, among which the central one was previously evaluated by micro-CT. Caries was rated using 6 graduations (sound, probably sound, white/brown spot, enamel caries, dentine caries limited to half of dentin depth, deep dentine caries). Micro-CT scans were acquired using a desktop system (SkyScan-1072, Belgium), based on a combination of X-ray projection microscopy and tomographic data reconstruction. In this system, an air-cooled X-ray point source (20-130 kV / 300 µA, focal spot size \textasciitilde{}8 mm) illuminates the object with a divergent beam, and magnified shadow pictures are detected by a 2D X-ray CCD camera (512 x 512 pixels). Cross-sectional images were reconstructed at a spatial resolution of 14µm3, using a Feldkamp cone-beam algorithm. Histological evaluation was performed using a Leitz hard tissue microtome (600 µm sections) and a stereomicroscope. Spearman{\textquoteright}s rank correlation analysis was performed between the histological, micro-CT, and clinical outcomes.Results: The micro-CT analysis demonstrated good agreement with histological measurements (r = 0.89, p < 0.001), whilst the clinical evaluations were found to be much less correlated with the micro-CT analysis (r = 0.39, p < 0.001) and histological data (r = 0.42, p < 0.001).Conclusion: Micro-CT imaging was shown to provide an interesting alternative to histological sectioning in the evaluation of caries diagnosis. As a nondestructive technique, micro-CT allows longitudinal evaluation of the same tooth material.